| Strategy | Implementation | |----------|----------------| | | Place joints near window corners (within 300mm) to concentrate movement away from opening. | | Corner reinforcement | Use L-shaped drywall corner beads or fiber mesh at 45° from window corners. | | Lintel design | Provide min 150mm bearing; use corrosion-resistant steel. | | Flexible sealants | All perimeter window-to-wall joints use elastomeric sealant, not rigid caulk. | | Sheathing continuity | OSB or plywood sheathing must be continuous around openings with blocked shear transfer. | | Window rough opening tolerance | Maintain 6–12mm gap around frame for shimming and foam insulation. |